SPECIFICATIONS |
MODEL |
6502 |
6503 |
6505 |
6510 |
6520 |
6530 |
6540 |
6560 |
INPUT |
Phase |
1ø |
3ø |
Voltage |
230Vac±15% |
220/380Vac±10% |
Frequency |
47-63Hz |
OUTPUT |
Max. Power |
2KVA |
3KVA |
5KVA |
10KVA |
20KVA |
30KVA |
40KVA |
60KVA |
Max. Current (r.m.s) *1 |
0-150V |
16.8A |
25.2A |
42.0A |
84.0A |
168.0A |
252.0A |
336.0A |
504.0A |
0-300V |
8.4A |
12.6A |
21.0A |
42.0A |
84.0A |
126.0A |
168.0A |
252.0A |
Max. Current (r.m.s) (Option 0-600V) *2 |
0-300V |
8.4A |
12.6A |
21.0A |
42.0A |
84.0A |
126.0A |
168.0A |
252.0A |
0-600V |
4.2A |
6.3A |
10.5A |
21.0A |
42.0A |
63.0A |
84.0A |
126.0A |
Phase |
1ø/2W |
Total Harmonic Distortion (T.H.D) |
< 1% at 47-63Hz (Resistive Load) |
Crest Factor |
>3 |
Line Regulation |
± 0.1V |
Load Regulation |
± (0.5% of output +0.5V) at Resistive Load |
Response Time |
< 2 msec |
SETTINGS |
Voltage |
Range |
0-150V/0-300V Selectable or 0-300V/0-600V Selectable(Option 0-600V) |
Resolution |
0.1V |
Accuracy |
±(1% of setting + 2counts) |
Frequency |
Range |
47.0-63.0Hz Full Range Adjust |
Resolution |
0.1Hz |
Accuracy |
±0.02% of setting |
MEASUREMENT |
Voltage |
Range |
0.0-300.0V / 0.0-600.0V(Option 0-600V) |
Resolution |
0.1V / 0.2V |
Accuracy |
± (1% of reading + 2counts) |
Frequency |
Range |
47.0-63.0Hz |
Resolution |
0.1Hz |
Accuracy |
±0.1Hz |
Current (r.m.s) |
Range |
L |
0.000-3.500A |
0.00-35.00A |
0.0 - 350.0A |
H |
3.00-35.00A |
30.00-350.0A |
300 - 3500A |
Resolution |
L |
0.001A |
0.01A |
0.1A |
H |
0.01A |
0.1A |
1A |
Accuracy |
L |
± (1% of reading +5counts) |
± (1% of reading +2counts) |
± (1% of reading +2counts) |
H |
± (1% of reading +1count) |
± (1% of reading +1count) |
Current (r.m.s) (Option 0-600V) |
Range |
L |
0.000-3.500A |
0.00-35.00A |
H |
3.00-35.00A |
30.00-350.0A |
Resolution |
L |
0.001A |
0.01A |
H |
0.01A |
0.1A |
Accuracy |
L |
± (1% of reading +5counts) |
± (1% of reading +2counts) |
H |
± (1% of reading +1count) |
± (1% of reading +1count) |
Power |
Range |
L |
0.0-350.0W |
0.000-3.500KW |
0.00-35.00KW |
H |
300-4000W |
3.00-40.00KW |
30.0-350.0KW |
Resolution |
L |
0.1W |
0.001KW |
0.01KW |
H |
1W |
0.01KW |
0.1KW |
Accuracy |
L |
± (1.5% of reading +5counts) |
H |
± (1.5% of reading +1count) |
Power Factor |
Range |
0.000-1.000 |
Resolution |
0.001 |
Accuracy |
W / V x A , Calculated and displayed to three significant digits |
GENERAL |
PLC Remote |
I/P:ON/OFF, P1, P2, P3, O/P:Processing |
Memory |
8 Memoies, 5steps per memory for Voltage, Frequency, Test Time, Delay time and Current, Power, Power Factor Hi, Lo Limit setting. |
Timer |
0=Continuous, 1-9999 (Unit: sec, minute, hour selectable) |
Auto Loop Cycle |
0=Continuous, OFF=Loop Once, 2~9999 (Unit:×1, ×10, ×100) |
Auto Voltage Adjust |
Enable it for improve voltage regulation within ±0.1V |
Efficiency |
≧80%(at Full Load ) |
≧85%(at Full Load ) |
Protection |
Over Load , Short Circuit , Over Temperature |
Calibration |
Front Panel Calibration |
Interface (Option) |
GPIB/RS232 |
Environment |
0-40℃/20-80%RH |
Dimension (W×H×D) mm |
430×222×650 |
430×222×650 |
430×222×650 |
430×489×650 |
430×756×650 |
600×978×900 |
600×978×900 |
800×1245×900 |
Dimension with Caster (W×H×D) mm |
430×306×650 |
430×306×650 |
430×306×650 |
430×573×650 |
430×863×650 |
600×1085×900 |
600×1085×900 |
800×1390×900 |
Dimension (W×H×D) mm (PFC) |
430×489×650 |
430×489×650 |
430×489×650 |
430×622×650 |
430×756×650 |
600×978×900 |
600×978×900 |
800×1245×900 |
Dimension with Caster (W×H×D) mm (PFC) |
430×573×650 |
430×573×650 |
430×573×650 |
430×729×650 |
430×863×650 |
600×1085×900 |
600×1085×900 |
800×1390×900 |
Net Weight |
40Kg |
47Kg |
69Kg |
150Kg |
216Kg |
372Kg |
402Kg |
487Kg |
Net Weight (PFC) |
66Kg |
83Kg |
119Kg |
226Kg |
346Kg |
536Kg |
600Kg |
760Kg |