SPECIFICATIONS | ||||
Withstanding Voltage | AC 5500V 1 minute max. (Between the core of CT and outer case) | |||
Storage Temperature | -10℃ to 60℃, 70%RH max. ( Without condensation ) | |||
Accuracy | (23℃±5℃, 80%RH or less) | |||
Function/Range/Accuracy/Maximum input | ||||
AC A (50/60Hz) Manual ranging/20A/±1.2% rdg ±10 dgt/AC600A | ||||
AC A (50/60Hz) Manual ranging/200A/±1.2% rdg ±10dgt/AC600A | ||||
AC A (50/60Hz) Manual ranging/600A/±1.0% rdg ± 8 dgt/AC600A | ||||
AC V (50/60Hz) DC V Auto ranging/2V/±0.7% rdg ± 5 dgt/DC 600V or AC 600V rms | ||||
AC V (50/60Hz) DC V Auto ranging/20V/±1.2% rdg ± 5 dgt/DC 600V or AC 600V rms | ||||
AC V (50/60Hz) DC V Auto ranging/200V/±1.2% rdg ± 5 dgt/DC 600V or AC 600V rms | ||||
AC V (50/60Hz) DC V Auto ranging/600V/±1.2% rdg ± 5 dgt/DC 600V or AC 600V rms | ||||
Resistance(Ω) Auto ranging/200Ω/±1.2% rdg ± 5 dgt/Input protection 250V rms (30 second) | ||||
Resistance(Ω) Auto ranging/2kΩ/±1.2% rdg ± 5 dgt/Input protection 250V rms (30 second) | ||||
Resistance(Ω) Auto ranging/20kΩ/±1.2% rdg ± 5 dgt/Input protection 250V rms (30 second) | ||||
Resistance(Ω) Auto ranging/200kΩ/±1.2% rdg ± 5 dgt/Input protection 250V rms (30 second) | ||||
Resistance(Ω) Auto ranging/2000kΩ/±1.2% rdg ± 5 dgt/Input protection 250V rms (30 second) | ||||
Resistance(Ω) Auto ranging/20MΩ/±3.0% rdg ±10 dgt/Input protection 250V rms (30 second) | ||||
Continuity check/2kΩ/Beeper < Approx. 300Ω/250V rms | ||||
Diode test/2V/±10% rdg ± 3dgt/250V rms | ||||
Operating Temperature | 0℃ to 40℃, 80%RH max. ( Without condensation ) | |||
Power supply | 1.5V (AM-4, LR03 or AAA)×2 | |||
Power consumption | 3.5mW | |||
Weight | Approx. 425g | |||
Safety standard | IEC 61010-1, IEC 61010-2-032 | |||
Installation CategoryⅢ600V phase to earth | ||||
Jaw opening capability | 40mmφ | |||
Size | 70(W)×223(H)×34(D)mm | |||
Accessories | Hard carrying case:1 | |||
Instruction manual:1 | ||||
Test lead:1set | ||||
Batteries:2 | ||||
Display | 3.5 digit LCD, max. reading of 1999 | |||
Over range indication | Blanking of all digits except MSD 1 | |||
Data hold indication | "DH" mark on LCD | |||
Low battery indication | "Battery" mark on LCD | |||
Auto power off | Approx. 10 minutes later after power on | |||
E.M.C. standard | EN 61326 | |||
Measuring method | Dual slope integration mode | |||
Battery life | Approx. 500 hours continuous | |||
Sampling | 2 times/sec | |||
상품의 사용후기를 적어주세요.
게시물이 없습니다
상품에 대해 궁금한 점을 해결해 드립니다.